.NET nanoFramework SX127X LoRa library RegLna LnaGain

Every so often I print my code out (landscape for notes in margin, double sided to save paper, and colour so it looks like Visual Studio 2022) and within 100 lines noticed the first of no doubt many issues. The SX127X RegLNA enumeration was wrong.

// RegLna
[Flags]
public enum RegLnaLnaGain : byte
{
	G1 = 0b00000001,
	G2 = 0b00000010,
	G3 = 0b00000011,
	G4 = 0b00000100,
	G5 = 0b00000101,
	G6 = 0b00000110
}
SX127X RegLna options

The LnaGain value is bits 5-7 rather than rather than bits 0-2 which could be a problem if the specified lnaGain and lnaBoost values are not the default values.

// Set RegLna if any of the settings not defaults
if ((lnaGain != Configuration.LnaGainDefault) || (lnaBoost != Configuration.LnaBoostDefault))
{
	byte regLnaValue = (byte)lnaGain;

	regLnaValue |= Configuration.RegLnaLnaBoostLfDefault;
	regLnaValue |= Configuration.RegLnaLnaBoostHfDefault;

	if (lnaBoost)
	{
		if (_frequency > Configuration.SX127XMidBandThreshold)
		{
			regLnaValue |= Configuration.RegLnaLnaBoostHfOn;
		}
		else
		{
			regLnaValue |= Configuration.RegLnaLnaBoostLfOn;
		}
	}
	_registerManager.WriteByte((byte)Configuration.Registers.RegLna, regLnaValue);
}

The default lnaGain is G1 and the default lnaBoost is false so if the gain was set to G3(011) then LnaBoostHf current would be 150% and LnaGain would be 000 which is a reserved value.

// RegLna
[Flags]
public enum RegLnaLnaGain : byte
{
	G1 = 0b00100000,
	G2 = 0b01000000,
	G3 = 0b01100000,
	G4 = 0b10000000,
	G5 = 0b10100000,
	G6 = 0b11000000
}

I need to check my usage of Configuration.SX127XMidBandThreshold for LnaBoostLf vs. LnaBoostHf is correct.(arduino-LoRa)