At CodeClub some of the students build a power consumption meter and as part of that project we measure the AnalogInput sample rates to check they are sufficient for our application.

Earlier this term when we measured the sampling rates in a CodeClub session we had a mix of Netduino 2 and Netduino 3 devices and some of the results differed from my previous observations. I used the same code on all the devices

int value;
AnalogInput x1 = new AnalogInput(Cpu.AnalogChannel.ANALOG_0);
stopwatch.Start();
for (int i = 0; i < SampleCount; i++)
{
value = x1.ReadRaw();
}
stopwatch.Stop();

Netduino Plus 2

Duration = 2081 mSec 48053/sec
Duration = 2082 mSec 48030/sec
Duration = 2081 mSec 48053/sec
Duration = 2081 mSec 48053/sec
Duration = 2082 mSec 48030/sec
Duration = 2081 mSec 48053/sec
Duration = 2081 mSec 48053/sec
Duration = 2081 mSec 48053/sec
Duration = 2081 mSec 48053/sec
Duration = 2081 mSec 48053/sec

Netduino 3

Duration = 2071 mSec 48285/sec
Duration = 2069 mSec 48332/sec
Duration = 2070 mSec 48309/sec
Duration = 2071 mSec 48285/sec
Duration = 2071 mSec 48285/sec
Duration = 2070 mSec 48309/sec
Duration = 2070 mSec 48309/sec
Duration = 2071 mSec 48285/sec
Duration = 2071 mSec 48285/sec
Duration = 2071 mSec 48285/sec

Netduino 3 Ethernet
Duration = 2136 mSec 46816/sec
Duration = 2137 mSec 46794/sec
Duration = 2136 mSec 46816/sec
Duration = 2135 mSec 46838/sec
Duration = 2135 mSec 46838/sec
Duration = 2137 mSec 46794/sec
Duration = 2137 mSec 46794/sec
Duration = 2135 mSec 46838/sec
Duration = 2136 mSec 46816/sec
Duration = 2135 mSec 46838/sec

Netduino 3 Wifii
Duration = 3902 mSec 25627/sec
Duration = 3901 mSec 25634/sec
Duration = 3902 mSec 25627/sec
Duration = 3902 mSec 25627/sec
Duration = 3901 mSec 25634/sec
Duration = 3903 mSec 25621/sec
Duration = 3903 mSec 25621/sec
Duration = 3902 mSec 25627/sec
Duration = 3902 mSec 25627/sec
Duration = 3903 mSec 25621/sec

The results for the Netduino 3 & Netduino 3 Ethernet were comparable with the Netduino Plus 2 in my earlier post. The reduction in the sampling rate of the Netduino 3 Wifi warrants some further investigation.

3 thoughts on “Netduino 3 AnalogInput read rates

  1. Pingback: Fez Lemur & Panda III AnalogInput read rates | devMobile's blog

  2. Pingback: Fez Cobra II Analog Input read rates | devMobile's blog

  3. Pingback: Fez Cobra III Analog Input read rates | devMobile's blog

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s